Please use this identifier to cite or link to this item: https://swslhd.intersearch.com.au/swslhdjspui/handle/1/13034
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAneman, A.-
dc.contributor.authorSkrifvars, M. B.-
dc.contributor.authorAmeloot, K.-
dc.date.accessioned2024-09-02T05:57:26Z-
dc.date.available2024-09-02T05:57:26Z-
dc.date.issued2024-
dc.identifier.issn2197425X (ISSN)-
dc.identifier.urihttps://swslhd.intersearch.com.au/swslhdjspui/handle/1/13034-
dc.description.abstractBackground: The European Resuscitation Council 2021 guidelines for haemodynamic monitoring and management during post-resuscitation care from cardiac arrest call for an individualised approach to therapeutic interventions. Combining the cardiac function and venous return curves with the inclusion of the mean systemic filling pressure enables a physiological illustration of intravascular volume, vasoconstriction and inotropy. An analogue mean systemic filling pressure (Pmsa) may be calculated once cardiac output, mean arterial and central venous pressure are known. The NEUROPROTECT trial compared targeting a mean arterial pressure of 65�mmHg (standard) versus an early goal directed haemodynamic optimisation targeting 85�mmHg (high) in ICU for 36�h after cardiac arrest. The trial data were used in this study to calculate post hoc Pmsa and its expanded variables to comprehensively describe venous return physiology during post-cardiac arrest management. A general estimating equation model was used to analyse continuous variables split by standard and high mean arterial pressure groups. Results: Data from 52 patients in each group were analysed. The driving pressure for venous return, and thus cardiac output, was higher in the high MAP group (p < 0.001) along with a numerically increased estimated stressed intravascular volume (mean difference 0.27 [? 0.014?0.55] L, p = 0.06). The heart efficiency was comparable (p = 0.43) in both the standard and high MAP target groups, suggesting that inotropy was similar despite increased arterial load in the high MAP group (p = 0.01). The efficiency of fluid boluses to increase cardiac output was increased in the higher MAP compared to standard MAP group (mean difference 0.26 [0.08?0.43] fraction units, p = 0.01). Conclusions: Calculation of the analogue mean systemic filling pressure and expanded variables using haemodynamic data from the NEUROPROTECT trial demonstrated an increased venous return, and thus cardiac output, as well as increased volume responsiveness associated with targeting a higher MAP. Further studies of the analogue mean systemic filling pressure and its derived variables are warranted to individualise post-resuscitation care and evaluate any clinical benefit associated with this monitoring approach. � Crown 2024.-
dc.publisherSpringer Nature-
dc.subjectCardiac arrest Haemodynamic management Mean systemic filling pressure dobutamine hemoglobin noradrenalin propofol remifentanil aged Article artificial ventilation blood transfusion central venous pressure clinical trial female heart arrest heart output heart ventricle ejection hemodynamics human hypothermia major clinical study male mean arterial pressure nuclear magnetic resonance imaging oxygen saturation post hoc analysis resuscitation venous return ventricular end diastolic pressure-
dc.titleVenous return physiology applied to post-cardiac arrest haemodynamic management: a post hoc analysis of the NEUROPROTECT trial-
dc.typeJournal Article-
dc.description.affiliatesIntensive Care Unit, Liverpool Hospital, South Western Sydney Local Health District and South Western Sydney Clinical School, University of New South Wales, Sydney, Australia The Ingham Institute for Applied Medical Research, Sydney, Australia Faculty of Health Sciences, Macquarie University, Sydney, Australia Department of Emergency Care and Services, Helsinki University Hospital and University of Helsinki, Helsinki, Finland Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium Departement de Cardiologie/Soins Intensifs Adultes, CHC-Montl�gia, Li�ge, Belgium Department of Cardiology, University Hospitals Leuven, Louvain, Belgium Faculty of Medicine and Life Sciences, University Hasselt, Diepenbeek, Belgium-
dc.identifier.doi10.1186/s40635-024-00657-0-
dc.type.studyortrialArticle-
dc.identifier.journaltitleIntensive Care Medicine Experimental-
Appears in Collections:Liverpool Hospital
South Western Sydney Local Health District

Files in This Item:
There are no files associated with this item.


Items in Prosentient are protected by copyright, with all rights reserved, unless otherwise indicated.

Google Media

Google ScholarTM

Who's citing